{"_buckets": {"deposit": "17d443a0-724c-4068-9562-0e31aea9119d"}, "_deposit": {"created_by": 15, "id": "2529", "owners": [15], "pid": {"revision_id": 0, "type": "depid", "value": "2529"}, "status": "published"}, "_oai": {"id": "oai:oacis.repo.nii.ac.jp:00002529", "sets": ["218", "665"]}, "author_link": ["371", "3983"], "item_3_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "101646", "bibliographicVolumeNumber": "9", "bibliographic_titles": [{"bibliographic_title": "MethodsX"}]}]}, "item_3_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The concentrations of small microplastics (diameter \u003c 350 µm) on filters are usually determined by microscopy or micro Fourier-transform infrared spectroscopy.\nThe presence of too many particles on a filter will cause the measured number of particles and particle sizes to be incorrect because of overlapping particles. In this study, the appropriate quantity of particles on a filter to allow effective particle analysis to be performed was determined by performing numerical experiments.\nThe larger the number of particles and the larger the particles, the smaller the proportion of isolated particles. An isolation ratio of 99% requires a particle density on the filter of 1.28 particles mm−2 if the particle size is 50 µm or of 0.351 particles mm−2 if the particle size is 100 µm.\n\n•Appropriate number of particles for small plastic particle analysis was determined.\n•Numerical experiments to determine particle distributions on a filter were performed.\n•Particle number for a 99% isolation ratio was determined.", "subitem_description_type": "Abstract"}]}, "item_3_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier B.V. "}]}, "item_3_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1016/j.mex.2022.101646", "subitem_relation_type_select": "DOI"}}]}, "item_3_relation_13": {"attribute_name": "情報源", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "Publisher\u0027s Version/PDF (OpenAccess)"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1016/j.mex.2022.101646", "subitem_relation_type_select": "DOI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "Elsevier B.V."}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.elsevier.com", "subitem_relation_type_select": "URI"}}]}, "item_3_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2215-0161", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Xu, Haodong"}], "nameIdentifiers": [{"nameIdentifier": "3983", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Arakawa, Hisayuki"}], "nameIdentifiers": [{"nameIdentifier": "371", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40242325", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40242325"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Isolation ratio", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Micro Fourier-transform infrared spectroscopy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Microplastic", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Numerical experiment", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Filter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Appropriate quantity", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Particle size distribution", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Simulator", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Determining the appropriate number of particles on a filter to allow small microplastics to be analyzed by microscopy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Determining the appropriate number of particles on a filter to allow small microplastics to be analyzed by microscopy"}]}, "item_type_id": "3", "owner": "15", "path": ["218", "665"], "permalink_uri": "https://oacis.repo.nii.ac.jp/records/2529", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-09-26"}, "publish_date": "2022-09-26", "publish_status": "0", "recid": "2529", "relation": {}, "relation_version_is_last": true, "title": ["Determining the appropriate number of particles on a filter to allow small microplastics to be analyzed by microscopy"], "weko_shared_id": -1}
Determining the appropriate number of particles on a filter to allow small microplastics to be analyzed by microscopy
https://oacis.repo.nii.ac.jp/records/2529
https://oacis.repo.nii.ac.jp/records/25297b4a6a27-1537-41e9-a63c-ff6e3476359a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-09-26 | |||||
タイトル | ||||||
タイトル | Determining the appropriate number of particles on a filter to allow small microplastics to be analyzed by microscopy | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題 | Isolation ratio, Micro Fourier-transform infrared spectroscopy, Microplastic, Numerical experiment, Filter, Appropriate quantity, Particle size distribution, Simulator | |||||
資源タイプ | ||||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
著者 |
Xu, Haodong
× Xu, Haodong× Arakawa, Hisayuki |
|||||
書誌情報 |
MethodsX 巻 9, p. 101646, 発行日 2022 |
|||||
抄録 | ||||||
内容記述 | The concentrations of small microplastics (diameter < 350 µm) on filters are usually determined by microscopy or micro Fourier-transform infrared spectroscopy. The presence of too many particles on a filter will cause the measured number of particles and particle sizes to be incorrect because of overlapping particles. In this study, the appropriate quantity of particles on a filter to allow effective particle analysis to be performed was determined by performing numerical experiments. The larger the number of particles and the larger the particles, the smaller the proportion of isolated particles. An isolation ratio of 99% requires a particle density on the filter of 1.28 particles mm−2 if the particle size is 50 µm or of 0.351 particles mm−2 if the particle size is 100 µm. •Appropriate number of particles for small plastic particle analysis was determined. •Numerical experiments to determine particle distributions on a filter were performed. •Particle number for a 99% isolation ratio was determined. |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2215-0161 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.mex.2022.101646 | |||||
情報源 | ||||||
関連識別子 | https://doi.org/10.1016/j.mex.2022.101646 | |||||
関連名称 | Publisher's Version/PDF (OpenAccess) | |||||
情報源 | ||||||
関連識別子 | https://www.elsevier.com | |||||
関連名称 | Elsevier B.V. | |||||
出版者 | ||||||
出版者 | Elsevier B.V. |